• Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
  • Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
  • Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
  • Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
  • Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
  • Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

After-sales Service: Within The Warranty to Provide Free Accessories
Warranty: 15 Months After Leaving The Factory
Type: Packaged Rooftop Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Non-Standard Custom
Operating Voltage: 380/400 VAC
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Features:
  • Install
  • Detailed Photos
  • Product Parameter(example)
  • Packing
Overview

Basic Info.

Model NO.
HAHUZ-240H
Noise Level
Ordinary
Application Fields
Apartment/Office Building/Gum/Supermarket/Factory
Mounting
Floor Standing
Lifetime
15~20 years
Certification
CCC
Condition
New
Compressor Brand
Copeland/Dai.Kin/Panasonic/Hitachi
Refrigerant
R22, R407c, R410A, R134A
Compressor Types
Flexible Eddy
Refrigerating Capacity
24kw-363kw
The Heating
25kw-381kw
Fan
Low Noise Centrifugal Fan
Machine Custom
According to The Demand for Custom-Made
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Trademark
HI-SURP
Origin
China
HS Code
8415
Production Capacity
1000pieces/Year

Product Description

Features:

Complete form and function
The roof unit produced by our company can be selected as single cooling type, heating and cooling heat pump type, single cooling plus electric heating type, or single cooling plus steam (hot water) heating type according to different usage requirements and working conditions of users. It can also be humidified and purified.

Complete form and function
The roof unit produced by our company can be used as single cooling type, heating and cooling heat pump type, single cooling plus electric heating type, or single cooling plus steam (hot water) heating type according to different usage requirements and working conditions of users. It can also be humidified and purified.
Easy installation and maintenance
The roof unit produced by our company adopts a fully-enclosed compressor. The compressor and the blower fan have vibration damping devices. The operation is quiet, so the foundation for the unit installation is simple. In addition, the unit has been strictly tested and adjusted in the factory. After installing the unit, just connect the return air duct and power cord, and it can be put into use. In the appropriate place, there are maintenance doors for easy maintenance. In addition, the random group provides a double-layer cleanable primary filter. Disassembly and cleaning are simple and convenient.
No occupation of indoor area, noise when operating in indoor inorganic group;
The roof units, compressors and system components produced by our company are all selected from famous brand manufacturers. After leaving the factory, they are strictly tested and adjusted. The units have high and low pressure protection, overcurrent protection, phase sequence protection and other functions. Durable
The roof unit produced by our company has two kinds of structure, aluminum profile frame structure and sheet metal frame structure. They are both solid and solid, with beautiful appearance.
The roof unit produced by our company adopts microcomputer control, LED large LCD screen display, with timing switch function, real-time clock display, etc. Optimized unit monitoring logic, well-designed unit operation data and fault alarm full-code query and prompt function, easy to operate.
The cooling capacity is from 24KW ~ 220KW, which is widely applicable to various large space civil, commercial buildings and industrial plants; such as large conference centers, stadiums, exhibition centers, large supermarkets, movie theaters, electronic factories, etc. Especially places with high requirements for noise or inconvenient indoor installation. Especially suitable for roof units.
 

Install

Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

Detailed Photos

 

Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit
Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

 

Product Parameter(example)



Return air type:

                             Model HAHU(Z)-10H HAHU(Z)-12H HAHU(Z)-17H HAHU(Z)-20H HAHU(Z)-22H HAHU(Z)-25H
Project                     Parameter
Unit characteristics Cooling capacity (kW) 10 12 17 20 22 25
Heating capacity
(heat pump)
(kW) 10.5  12.6  17.9  21.0  23.1  26.3 
Auxiliary electric heating (optional) (kW) 4.5  4.5  6.0  6.0  9.0  9.0 
Circulation
air volume
(m3/h) 2000 2400 3600 4200 4600 5200
Outside static pressure range (Pa) 50~200 50~200 100~300 100~300 100~300 100~300
Temperature control
 range and accuracy
  18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC
Energy regulation % 0-100 0-100 0-100 0-100 0-100 0-100
power supply   3P-AC380V/
50HZ/N/PE
3P-AC380V/
50HZ/N/PE
3P-AC380V/
50HZ/N/PE
3P-AC380V/
50HZ/N/PE
3P-AC380V/
50HZ/N/PE
3P-AC380V/
50HZ/N/PE
Operating power
(minimum static pressure)
(kW) 3.9  4.7  6.6  7.8  8.6  9.8 
Electrical parameters
- no electric heating
Maximum
operating power
5.1  6.1  8.6  10.2  11.2  12.7 
reference current 9.6  11.5  16.4  19.2  21.2  24.0 
Recommended incoming line specification
(mm2)
2.5  2.5  4.0  4.0  6.0  6.0 
Electrical parameters
 - with electric heating
Maximum
operating power
9.6  10.6  14.6  16.2  20.2  21.7 
reference current 18.1  20.1  27.7  30.6  38.2  41.1 
Recommended incoming line specification
(mm2)
6.0  6.0  6.0  10.0  10.0  10.0 
air conditioning part Primary filter Type and grade Plate G3/G4 Plate G3/G4 Plate G3/G4 Plate G3/G4 Plate G3/G4 Plate G3/G4
Intermediate filter
(optional)
Type and grade Plate FB5 Plate FB5 Plate FB5 Plate FB5 Plate FB5 Plate FB5
Evaporator Type Hydrophilic louver type aluminum fins Hydrophilic louver type aluminum fins Hydrophilic louver type aluminum fins Hydrophilic louver type aluminum fins Hydrophilic louver type aluminum fins Hydrophilic louver type aluminum fins
direct wind speed <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5
Throttling mode   Expansion valve Expansion valve Expansion valve Expansion valve Expansion valve Expansion valve
Auxiliary electric heating
(Optional)
Electric heating type PTC ceramics PTC ceramics PTC ceramics PTC ceramics PTC ceramics PTC ceramics
Power (kW) 4.5 4.5 6 6 9 9
Diameter of drain pipe DN DN25 DN25 DN25 DN25 DN25 DN25
Blower Type Low noise centrifugal fan Low noise centrifugal fan Low noise centrifugal fan Low noise centrifugal fan Low noise centrifugal fan Low noise centrifugal fan
transfer method pulley drive pulley drive pulley drive pulley drive pulley drive pulley drive
Fan model KTS7-7C KTS7-7C KTS10-10 KTS10-10 KTS12-9 KTS12-9
Fan qty 1 1 1 1 1 1
Air outlet size 259×228 259×228 331×289 331×289 309×341 309×341
compression condensing part Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll
QTY 1 1 1 1 1 1
Refrigerant Refrigerant model R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22
Filling amount kg 3.0  3.6  5.1  6.0  6.6  7.5 
Condenser Type Copper tube aluminum fin Copper tube aluminum fin Copper tube aluminum fin Copper tube aluminum fin Copper tube aluminum fin Copper tube aluminum fin
Fan part Fan type Axial fan blade Axial fan blade Axial fan blade Axial fan blade Axial fan blade Axial fan blade
Fan model RZLC550 RZLC550 RZLC600 RZLC600 RZLC650 RZLC650
QTY 1 1 1 1 1 1
Air volume(m3/h) 5600 5600 8040 8040 9930 9930
Power (kW) 0.37 0.37 0.37 0.37 0.55 0.55
Dimensions Length (mm) 1260 1260 1360 1360 1460 1460
Width (mm) 900 900 1000 1000 1100 1100
Height (mm) 1160 1160 1260 1260 1460 1460
Weight (Kg) 200 220 320 340 420 460
Noise (dB) A 66 66 67 68 72 72

Note:
1. Rated cooling capacity test conditions: outdoor dry bulb 35°C, indoor dry bulb/wet bulb 27°C/19°C
2. Rated heating test conditions: outdoor dry bulb/wet bulb 7°C/6°C, indoor dry bulb 20°C
3. When heating, the ambient temperature is lower than 0°C, it is recommended to use electric heating.
4. The static pressure of the unit in the fan characteristics is selected according to the integral multiple of 50 within the given static pressure range.

 

Packing

Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

Hisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner UnitHisurp HAVC R407c, R410A, R134A Rooftop Package Unit Air Conditioner Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
291
Year of Establishment
2003-05-22