Customization: | Available |
---|---|
After-sales Service: | Within The Warranty to Provide Free Accessories |
Warranty: | 15 Months After Leaving The Factory |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Feature
The constant temperature and humidity unit is equipped with a Chinese display operator. The working status and parameter query settings are all displayed in Chinese. It is also equipped with a complete fault alarm indicator system, which greatly facilitates the user. Microcomputer has more constant dehumidification control energy levels than other manufacturers. Make the control more precise and avoid large deviation of indoor temperature fluctuation during adjustment.
The constant temperature and humidity unit is equipped with a Chinese display operator. The working status and parameter query settings are all displayed in Chinese. It is also equipped with a complete fault alarm indicator system, which greatly facilitates the user. More, make the control more accurate, avoid large temperature and humidity fluctuations during adjustment
Six or more models adopt independent dual system and three-level electric heating system, which makes the temperature and humidity adjustment of the unit more precise, more efficient and energy saving, and achieves control accuracy.
All models use imported high-quality electrode humidifiers, which can use a variety of tap water, and tap water can be used directly without water treatment; the humidifier can adjust the steam output, making the unit humidity adjustment very fine to achieve high control accuracy.
The design of the unit is flexible. Wellcome has a variety of methods such as direct air, upper air supply and lower air supply, which can easily meet the needs of field installation. Adopting the skeleton structure, the rigidity of the internal fittings is higher, which reduces the vibration and noise of the unit. Each shell plate is pasted with a sufficient thickness of thermal insulation and sound-absorbing materials, and can be easily removed.
The fan adopts forward curved multi-wing centrifugal double-suction impeller, and the impeller has no noise vibration during long-term operation to ensure a high degree of air supply effect. The belt drive can flexibly change the parameters such as unit air volume and external pressure, so Matching with the actual project; the fan comes with a motor adjustment plate, which can easily adjust the tightness of the belt.
Smart and simple design makes maintenance and repair extremely convenient. All the unit's accessories can be inspected and repaired directly from the front, and there is no need to stop.
Refrigeration range
The cooling capacity is from 7kW to 300kW.. It is widely used in workshops and centralized control rooms in machinery manufacturing, steel, chemical, electronics, pharmaceutical and other industries, as well as restaurants, hotels, clubs, and other commercial air-conditioning places to meet industries in different environments. The need for process air conditioning and commercial comfort air conditioning.
No matter whether it is reconstruction or reconstruction, since there is no need to set up a dedicated air-conditioning room, the freedom to choose a place to install is large, so that your space of responsibility is wide. At the same time, FFU can be used in a wide range of hospital waiting rooms, nursing staff offices, lounges, etc. The problem of clean air.
product parameters(example)
Model | HAHU(Z)-35H | HAHU(Z)-40H | HAHU(Z)-45H | HAHU(Z)-50H | HAHU(Z)-60H | HAHU(Z)-70H | HAHU(Z)-80H | HAHU(Z)-90H | HAHU(Z)-100H | HAHU(Z)-120H | HAHU(Z)-140H | HAHU(Z)-180H | HAHU(Z)-210H | HAHU(Z)-240H | HAHU(Z)-280H | HAHU(Z)-300H | HAHU(Z)-350H | HAHU(Z)-360H | HAHU(Z)-420H | ||
Parameter | |||||||||||||||||||||
Unit charactries | Cooling Capacity | (kW) | 35 | 40 | 45 | 50 | 60 | 70 | 80 | 90 | 105 | 120 | 140 | 180 | 210 | 240 | 280 | 300 | 350 | 360 | 420 |
Heating Capacity (Heat Pump) | (kW) | 36.8 | 42.0 | 47.3 | 52.5 | 63.0 | 73.5 | 84.0 | 94.5 | 110.3 | 126.0 | 147.0 | 189.0 | 220.5 | 252.0 | 294.0 | 315.0 | 367.5 | 378.0 | 441.0 | |
)Auxiliary electric heating (optional) | (kW) | 12.0 | 18.0 | 18.0 | 24.0 | 24.0 | 24.0 | 36.0 | 36.0 | 48.0 | 48.0 | 60.0 | 60.0 | 72.0 | 72.0 | 96.0 | 96.0 | 108.0 | 108.0 | 120.0 | |
Circulation Air Flow | (m3/h) | 6600 | 7600 | 8200 | 9400 | 11600 | 12800 | 15000 | 16000 | 18000 | 22000 | 26000 | 32000 | 37000 | 42000 | 49000 | 52000 | 61000 | 63000 | 72000 | |
ESP Range | (Pa) | 100~400 | 100~400 | 200~500 | 200~500 | 200~600 | 200~600 | 200~600 | 200~600 | 200~600 | 200~800 | 200~800 | 300~800 | 300~800 | 300~800 | 300~800 | 300~800 | 300~800 | 300~800 | 300~800 | |
Temperature Control Range &Accuracy | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | ||
Engery Regulation | % | 0-100 | 0-100 | 0-50-100 | 0-50-100 | 0-50-100 | 0-50-100 | 0-50-100 | 0-50-100 | 0-33-66-100 | 0-50-100 | 0-50-100 | 0-33-66-100 | 0-33-66-100 | 0-25-50-75-100 | 0-25-50-75-100 | 0-20-40-60-80-100 | 0-20-40-60-80-100 | 0-33-66-100 | 0-33-66-100 | |
Power Supply | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | ||
Operation Power(Minnimum static pressure) | (kW) | 13.7 | 15.6 | 17.6 | 19.5 | 23.4 | 27.3 | 31.3 | 35.2 | 41.0 | 46.9 | 54.7 | 70.3 | 82.0 | 93.8 | 109.4 | 117.2 | 136.7 | 140.6 | 164.1 | |
Electrical Parameters-No elctric heating | Max.Operation Power | 17.8 | 20.3 | 22.9 | 25.4 | 30.5 | 35.5 | 40.6 | 45.7 | 53.3 | 60.9 | 71.1 | 91.4 | 106.6 | 121.9 | 142.2 | 152.3 | 177.7 | 182.8 | 213.3 | |
Ref.Current | 33.7 | 38.5 | 43.3 | 48.1 | 57.7 | 67.3 | 76.9 | 86.6 | 101.0 | 115.4 | 134.6 | 173.1 | 202.0 | 230.8 | 269.3 | 288.5 | 336.6 | 346.2 | 403.9 | ||
wire inlet specification (mm2) | 10.0 | 10.0 | 10.0 | 10.0 | 16.0 | 16.0 | 25.0 | 25.0 | 25.0 | 35.0 | 35.0 | 50.0 | 70.0 | 95.0 | 95.0 | 120.0 | 150.0 | 150.0 | 185.0 | ||
Electric Parameters-Ekectric heating | Max.operation Power | 29.8 | 38.3 | 40.9 | 49.4 | 54.5 | 59.5 | 76.6 | 81.7 | 101.3 | 108.9 | 131.1 | 151.4 | 178.6 | 193.9 | 238.2 | 248.3 | 285.7 | 290.8 | 333.3 | |
Ref.Current | 56.4 | 72.6 | 77.4 | 93.5 | 103.2 | 112.8 | 145.1 | 154.7 | 191.9 | 206.3 | 248.3 | 286.8 | 338.3 | 367.2 | 451.1 | 470.3 | 541.2 | 550.8 | 631.2 | ||
wire inlet specification (mm2) | 16.0 | 16.0 | 25.0 | 25.0 | 25.0 | 35.0 | 50.0 | 50.0 | 70.0 | 70.0 | 95.0 | 120.0 | 150.0 | 185.0 | 240.0 | 300.0 | 300.0 | 400.0 | 400.0 | ||
Air Regulant Section | primary filter | Type$Class | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 |
Middle filter(optional) | Type$Class | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | |
Evaporator | Type | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | |
Windward Speed | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | <=2.5 | ||
Throttling Mode | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | expansion value | ||
Auxiliary Electric heating(optional) | Electric heating mode | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | PTC cermics | |
Power(kW) | 12 | 18 | 18 | 24 | 24 | 24 | 36 | 36 | 48 | 48 | 60 | 60 | 72 | 72 | 96 | 96 | 108 | 108 | 120 | ||
Pipe Diameter | DN | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN32 | DN32 | DN32 | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 | |
Supply Fan | Type | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | |
transmission mode | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | belt drive | ||
Fan Type | KTS12-12 | KTS15-15 | KTS15-15 | KTS15-15 | KTS20-15 | KTS20-15 | KTS20-15 | KTS20-20 | KTS20-20 | EDK5.6A | EDK5.6A | EDK6.3A | EDK7.1A | EDK7.1A | EDK8.0A | EDK8.0A | EDK6.3A | EDK6.3A | EDK7.1A | ||
Fan Quantity | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Fan Dimension | 395×341 | 471×404 | 471×404 | 471×404 | 502×630 | 502×630 | 502×630 | 630×630 | 630×630 | 740×650 | 740×650 | 785×700 | 950×780 | 950×780 | 1080×860 | 1080×860 | 785×700×2 | 785×700×2 | 950×780×2 | ||
compressor condesder Section\ | Compressor | Type | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex |
Quantity | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 5 | 5 | 6 | 6 | ||
Refrigerat | Refrigerant Model | R410A/R22 | R410A/R22 | R410A/R22 | R410A/R22 | R410A/R22 | R410A/R22 | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | |
filling Capacitykg | 10.5 | 12.0 | 13.5 | 7.5×2 | 9×2 | 10.5×2 | 12×2 | 13.5×2 | 13.5×16 | 16×2 | 19×2 | 16×3 | 19×3 | 16×4 | 19×4 | 16×5 | 19×5 | 16×6 | 19×6 | ||
Condenser | Type | vCopper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | |
Fan Section | Fan type | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | Axial fan | |
fan Model | RZLC750 | RZLC750 | RZLC650 | RZLC650 | RZLC750 | RZLC750 | RZLC750 | RZLC650 | RZLC650 | RZLC750 | RZLC750 | RZLC751 | RZLC751 | RZLC751 | RZLC751 | RZLC751 | RZLC751 | RZLC751 | RZLC751 | ||
Quantity | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 6 | 6 | 8 | 8 | 10 | 10 | 12 | 12 | ||
Air Flow(m3/h) | 14360 | 14360 | 9930 | 9930 | 14360 | 14360 | 14360 | 9930 | 9930 | 14360 | 14360 | 14360 | 14360 | 14360 | 14360 | 14360 | 14360 | 14360 | 14360 | ||
Power(kW) | 1.1 | 1.1 | 0.55 | 0.55 | 1.1 | 1.1 | 1.1 | 0.55 | 0.55 | 1.1 | 1.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | ||
Outline Dimension | Length(mm) | 1760 | 1760 | 1860 | 1860 | 2260 | 2260 | 2260 | 3200 | 3200 | 4300 | 4300 | 5750 | 6050 | 7500 | 8000 | 9050 | 9650 | 10700 | 11300 | |
Width(mm) | 1300 | 1300 | 2000 | 2000 | 2050 | 2050 | 2050 | 2050 | 2050 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | ||
Height(mm) | 1660 | 1660 | 1760 | 1760 | 1860 | 1860 | 1860 | 1860 | 1860 | 2344 | 2344 | 2344 | 2344 | 2344 | 2344 | 2344 | 2344 | 2344 | 2344 | ||
Weight(Kg) | 560 | 600 | 660 | 700 | 820 | 860 | 900 | 1200 | 1360 | 1780 | 1860 | 2600 | 2800 | 3000 | 3400 | 3800 | 4200 | 4600 | 4800 | ||
Noise(dB)A | 76 | 68 | 72 | 72 | 76 | 76 | 72 | 76 | 76 | 76 | 76 | 78 | 79 | 78 | 79 | 78 | 79 | 78 | 79 | ||
Note: | |||||||||||||||||||||
1, Rated Refrigeration Capacity TestCondition:Outdoor dry ball 35ºC,indoor dry ball/wet ball 27ºC/19ºC | |||||||||||||||||||||
2,Rated heating test conditon:Outdoor dry ball/wet ball 7ºC/6ºC,indoor dry ball/wet ball 20ºC | |||||||||||||||||||||
3,The ambient temperature is below 0ºC when heating ,it is recommed to use electric heating | |||||||||||||||||||||
4,The static pressure of the unit in the fan characteristics is selected as an integer multiple of 50 within the given static pressure range. | |||||||||||||||||||||