Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing

Product Details
Customization: Available
After-sales Service: Within The Warranty to Provide Free Accessories
Warranty: 15 Months After Leaving The Factory
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
291
Year of Establishment
2003-05-22
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
  • Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
HAHUN-10H
Type
Packaged Rooftop Air Conditioner
Air Tube Material
Galvanized Sheet
Corrosion Durability
Non-Standard Custom
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Apartment/Office Building/Gum/Supermarket/Factory
Mounting
Floor Standing
Lifetime
15~20 years
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Compressor Brand
Copeland/Dai.Kin/Panasonic/Hitachi
Refrigerant
R22, R407c, R410A, R134A
Compressor Types
Flexible Eddy
Cooling Capacity
24kw-363kw
Heating Capacity
25kw-381kw
Fan
Low Noise Centrifugal Fan
Machine Custom
According to The Demand for Custom-Made
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Trademark
HI-SURP
Origin
China
HS Code
8415
Production Capacity
1000pieces/Year

Product Description

Detailed Photos
Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing

 
Product Parameters
                          Model HAHU(Z)-10H HAHU(Z)-12H HAHU(Z)-17H HAHU(Z)-20H HAHU(Z)-22H HAHU(Z)-25H HAHU(Z)-30H HAHU(Z)-35H HAHU(Z)-40H HAHU(Z)-45H HAHU(Z)-50H HAHU(Z)-60H HAHU(Z)-70H HAHU(Z)-80H HAHU(Z)-90H HAHU(Z)-100H HAHU(Z)-120H HAHU(Z)-140H HAHU(Z)-180H HAHU(Z)-210H HAHU(Z)-240H HAHU(Z)-280H HAHU(Z)-300H HAHU(Z)-350H HAHU(Z)-360H HAHU(Z)-420H
           Parameter
Unit charactries  Cooling Capacity (kW) 10 12 17 20 22 25 30 35 40 45 50 60 70 80 90 105 120 140 180 210 240 280 300 350 360 420
Heating Capacity (Heat Pump) (kW) 10.5  12.6  17.9  21.0  23.1  26.3  31.5  36.8  42.0  47.3  52.5  63.0  73.5  84.0  94.5  110.3  126.0  147.0  189.0  220.5  252.0  294.0  315.0  367.5  378.0  441.0 
)Auxiliary electric heating (optional) (kW) 4.5  4.5  6.0  6.0  9.0  9.0  12.0  12.0  18.0  18.0  24.0  24.0  24.0  36.0  36.0  48.0  48.0  60.0  60.0  72.0  72.0  96.0  96.0  108.0  108.0  120.0 
Circulation Air Flow (m3/h) 2000 2400 3600 4200 4600 5200 6400 6600 7600 8200 9400 11600 12800 15000 16000 18000 22000 26000 32000 37000 42000 49000 52000 61000 63000 72000
ESP Range (Pa) 50~200 50~200 100~300 100~300 100~300 100~300 100~400 100~400 100~400 200~500 200~500 200~600 200~600 200~600 200~600 200~600 200~800 200~800 300~800 300~800 300~800 300~800 300~800 300~800 300~800 300~800
Temperature Control Range &Accuracy   18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC 18ºC~30ºC±1ºC
Engery Regulation % 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-50-100 0-33-66-100 0-50-100 0-50-100 0-33-66-100 0-33-66-100 0-25-50-75-100 0-25-50-75-100 0-20-40-60-80-100 0-20-40-60-80-100 0-33-66-100 0-33-66-100
Power Supply   3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE 3P-AC380V/50HZ/N/PE
Operation Power(Minnimum static pressure) (kW) 3.9  4.7  6.6  7.8  8.6  9.8  11.7  13.7  15.6  17.6  19.5  23.4  27.3  31.3  35.2  41.0  46.9  54.7  70.3  82.0  93.8  109.4  117.2  136.7  140.6  164.1 
Electrical Parameters-No elctric heating Max.Operation Power 5.1  6.1  8.6  10.2  11.2  12.7  15.2  17.8  20.3  22.9  25.4  30.5  35.5  40.6  45.7  53.3  60.9  71.1  91.4  106.6  121.9  142.2  152.3  177.7  182.8  213.3 
Ref.Current 9.6  11.5  16.4  19.2  21.2  24.0  28.9  33.7  38.5  43.3  48.1  57.7  67.3  76.9  86.6  101.0  115.4  134.6  173.1  202.0  230.8  269.3  288.5  336.6  346.2  403.9 
wire inlet specification (mm2) 2.5  2.5  4.0  4.0  6.0  6.0  6.0  10.0  10.0  10.0  10.0  16.0  16.0  25.0  25.0  25.0  35.0  35.0  50.0  70.0  95.0  95.0  120.0  150.0  150.0  185.0 
Electric Parameters-Ekectric heating Max.operation Power 9.6  10.6  14.6  16.2  20.2  21.7  27.2  29.8  38.3  40.9  49.4  54.5  59.5  76.6  81.7  101.3  108.9  131.1  151.4  178.6  193.9  238.2  248.3  285.7  290.8  333.3 
Ref.Current 18.1  20.1  27.7  30.6  38.2  41.1  51.6  56.4  72.6  77.4  93.5  103.2  112.8  145.1  154.7  191.9  206.3  248.3  286.8  338.3  367.2  451.1  470.3  541.2  550.8  631.2 
wire inlet specification (mm2) 6.0  6.0  6.0  10.0  10.0  10.0  10.0  16.0  16.0  25.0  25.0  25.0  35.0  50.0  50.0  70.0  70.0  95.0  120.0  150.0  185.0  240.0  300.0  300.0  400.0  400.0 
Air Regulant Section primary filter Type$Class panelG3/G4
Middle filter(optional) Type$Class PanelFB5
Evaporator Type Hydrophilic shutter type aluminium fins
Windward Speed <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5 <=2.5
Throttling Mode   expansion value
Auxiliary Electric heating(optional) Electric heating mode PTC cermics
Power(kW) 4.5 4.5 6 6 9 9 12 12 18 18 24 24 24 36 36 48 48 60 60 72 72 96 96 108 108 120
 Pipe Diameter DN DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN25 DN32 DN32 DN32 DN32 DN32 DN40 DN40 DN40 DN40 DN40 DN40 DN40 DN40 DN40 DN40
Supply Fan Type  low noise centrifugal fan
transmission mode belt drive
Fan Type KTS7-7C KTS7-7C KTS10-10 KTS10-10 KTS12-9 KTS12-9 KTS12-12 KTS12-12 KTS15-15 KTS15-15 KTS15-15 KTS20-15 KTS20-15 KTS20-15 KTS20-20 KTS20-20 EDK5.6A EDK5.6A EDK6.3A EDK7.1A EDK7.1A EDK8.0A EDK8.0A EDK6.3A EDK6.3A EDK7.1A
Fan Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2
Fan Dimension 259×228 259×228 331×289 331×289 309×341 309×341 395×341 395×341 471×404 471×404 471×404 502×630 502×630 502×630 630×630 630×630 740×650 740×650 785×700 950×780 950×780 1080×860 1080×860 785×700×2 785×700×2 950×780×2
compressor condesder Section\ Compressor Type  Vortex
Quantity 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 3 3 4 4 5 5 6 6
Refrigerat Refrigerant Model R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A/R22 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
filling Capacitykg 3.0  3.6  5.1  6.0  6.6  7.5  9.0  10.5  12.0  13.5  7.5×2 9×2 10.5×2 12×2 13.5×2 13.5×16 16×2 19×2 16×3 19×3 16×4 19×4 16×5 19×5 16×6 19×6
Condenser Type Copper tube Aluminiun fins
Fan Section Fan type Axial fan
fan Model RZLC550 RZLC550 RZLC600 RZLC600 RZLC650 RZLC650 RZLC750 RZLC750 RZLC750 RZLC650 RZLC650 RZLC750 RZLC750 RZLC750 RZLC650 RZLC650 RZLC750 RZLC750 RZLC751 RZLC751 RZLC751 RZLC751 RZLC751 RZLC751 RZLC751 RZLC751
Quantity 1 1 1 1 1 1 1 1 1 2 2 2 2 2 4 4 4 4 6 6 8 8 10 10 12 12
Air Flow(m3/h) 5600 5600 8040 8040 9930 9930 14360 14360 14360 9930 9930 14360 14360 14360 9930 9930 14360 14360 14360 14360 14360 14360 14360 14360 14360 14360
Power(kW) 0.37 0.37 0.37 0.37 0.55 0.55 1.1 1.1 1.1 0.55 0.55 1.1 1.1 1.1 0.55 0.55 1.1 1.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1
Outline Dimension Length(mm) 1260 1260 1360 1360 1460 1460 1760 1760 1760 1860 1860 2260 2260 2260 3200 3200 4300 4300 5750 6050 7500 8000 9050 9650 10700 11300
Width(mm) 900 900 1000 1000 1100 1100 1300 1300 1300 2000 2000 2050 2050 2050 2050 2050 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200
Height(mm) 1160 1160 1260 1260 1460 1460 1660 1660 1660 1760 1760 1860 1860 1860 1860 1860 2344 2344 2344 2344 2344 2344 2344 2344 2344 2344
Weight(Kg) 200 220 320 340 420 460 500 560 600 660 700 820 860 900 1200 1360 1780 1860 2600 2800 3000 3400 3800 4200 4600 4800
Noise(dB)A 66 66 67 68 72 72 76 76 68 72 72 76 76 72 76 76 76 76 78 79 78 79 78 79 78 79
                                                         
Note:                                                        
1, Rated Refrigeration Capacity TestCondition:Outdoor dry ball 35ºC,indoor dry ball/wet ball 27ºC/19ºC                              
2,Rated heating test conditon:Outdoor dry ball/wet ball 7ºC/6ºC,indoor dry ball/wet ball 20ºC                              
3,The ambient temperature is below 0ºC when heating ,it is recommed to use electric heating                              
4,The static pressure of the unit in the fan characteristics is selected as an integer multiple of 50 within the given static pressure range.                              



Dimensions:

Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing



 


Features

 



 
- G1-G4 initial filter
 
- Programmable Controllers
 
- Microcomputer control
 
- Cooling capacity:24kW~363kW
 
- 3ph/380V/50Hz

                         - LED screen display
 
                         - Suitable for areas where water is scarce
 
                         - Low noise centrifugal fan
 
                         - Emerson expansion valve





Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing


                                                                                                                                                                                                             

Details:

1. Heating and cooling heat pump type, single cooling plus electric heating type, or single cooling plus steam (hot water) heating type.

2. Easy installation and maintenance

3. Fully enclosed compressor. Compressor and the air supply fan have vibration damping devices. Operation is quiet, so the installation basis of the unit is simple.

4. Provides a double-layer washable primary filter. Disassembly and cleaning are simple and convenient.

5. Not occupy the indoor area, and the noise during the operation of the indoor inorganic group.

5. Unit has high and low pressure protection, overcurrent protection, phase sequence protection and other functions with high reliability. Durable.

6. Aluminum profile frame structure and sheet metal frame structure can select.

7. Microcomputer, large LED screen, has the function of timing switch, real-time clock display, etc. Optimized unit monitoring logic, well-designed unit operating data and fault alarm full code query and prompt functions, easy to operate.

8. Widely used in various large-space civil, commercial buildings and industrial plants; such as large conference centers, stadiums, exhibition centers, large supermarkets, theaters, electronic plants,desert etc.
Packing
Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing


                                                                                                                                                                                                

Floor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export PackingFloor Standing Air-Cooled Chiller Packaged Rooftop Air Conditioner Unit with Fully Enclosed Export Packing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier