Customization: | Available |
---|---|
After-sales Service: | Within The Warranty to Provide Free Accessories |
Warranty: | 15 Months After Leaving The Factory |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Wholesale Air Conditioning Supply Splite Type Air-cooled Air Conditioning is widely used in all kinds of
Direct Air Supply Type--Refrigerant: R22/R410A/R407C/R134A
Compressor Outside (Indoor Unit B Type + Outdoor Unit B Type)
Indoor Unit Model Project Parameter |
HASD1-80WH-B | HASD1-120WH-B | HASD1-140WH-B | HASD1-170WH-B | HASD1-210WH-B | HASD1-250WH-B | ||||
Unit Characteristic | Refrigerating Capacity | kW | 8.2 | 12.0 | 14.6 | 17.5 | 20.4 | 25.0 | ||
Heating Capacity | kW | 8.6 | 12.5 | 15.3 | 18.4 | 21.4 | 26.3 | |||
Cold Wind Electric Heating Power (optional) | kW | 5 | 8 | 8 | 9 | 11 | 15 | |||
Cold Air To Increase Electric Heating (optional) | kW | 7.5 | 12 | 12 | 14 | 17 | 22 | |||
Heat Pump Electric Auxiliary Heating (optional) | kW | 3 | 4.5 | 4.5 | 5 | 6 | 8 | |||
Refrigerating Power | kW | 2.7 | 3.9 | 4.8 | 5.7 | 6.7 | 8.3 | |||
Heating Power | kW | 2.75 | 4.05 | 4.9 | 5.8 | 6.9 | 8.5 | |||
Circulation Air Flow | m3/h | 1550 | 2200 | 2700 | 3000 | 3500 | 4500 | |||
External Static Pressure | Pa | 0 | ||||||||
Indoor Unit Noise | dB(A) | ≤56 | ≤57 | ≤58 | ≤60 | ≤60 | ≤62 | |||
Connection of Liquid Pipe | inch | φ3/8 | φ1/2 | φ1/2 | φ1/2 | φ1/2 | φ1/2x2 | |||
Connection of Exhaust Pipe | inch | φ5/8 | φ3/4 | φ3/4 | φ3/4 | φ3/4 | φ3/4x2 | |||
Piping Direction | Facing front left, right connecting pipes | |||||||||
Power Supply | 380V 3N~50Hz | |||||||||
Outdoor Unit qty | set | 1 | 1 | 1 | 1 | 1 | 1 | |||
Outdoor Unit | Outdoor Unit Model | HAS-80WHS-B | HAS-120WHS-B | HAS-140WHS-B | HAS-170WHS-B | HAS-210WHS-B | HAS-250WHD-B | |||
Compressor | Type | Fully enclosed rotor type | Fully enclosed scroll type | |||||||
qty | 1 | 1 | 1 | 1 | 1 | 2 | ||||
Power Supply | 380V 3N~50Hz | |||||||||
Refrigerant | Type | R22 | ||||||||
Filling Amount Kg | 3.2 | 4.4 | 5.0 | 5.6 | 6.3 | 4.4x2 | ||||
Condenser | Type | Copper tube series casing fin type | ||||||||
Fin Type | High efficient corrugated aluminum fins | |||||||||
Condensing Fan | Type | Low Noise Axial Flow Fan | ||||||||
Power | kW | 0.07 | 0.06 x2 | 0.06 x2 | 0.55 | 0.55 | 0.55 | |||
Outline Dimension | W | mm | 953 | 953 | 953 | 720 | 720 | 815 | ||
D | mm | 353 | 353 | 353 | 720 | 720 | 815 | |||
H | mm | 840 | 1235 | 1235 | 1050 | 1050 | 1150 | |||
Outdoor Unit Noise | dB(A) | ≤58 | ≤60 | ≤60 | ≤62 | ≤62 | ≤64 | |||
Weight | kg | 75 | 120 | 125 | 150 | 180 | 210 | |||
Indoor Unit | Evaporator | Type | Internal threaded Copper tube series casing fin type | |||||||
Fin Type | Shutter-type hydrophilic film aluminum fins | |||||||||
Throttling Method | Externally balanced thermal expansion valve | |||||||||
Fan | Type | Low Noise Centrifugal Fan | ||||||||
Driving Mode | Direct motor drive | |||||||||
Power | kW | 0.18 | 0.18 | 0.18 | 0.25 | 0.37 | 0.4 | |||
Electric Heating Type | Stainless steel pipe tension wrapped fin type | |||||||||
Air Filter | Initial-effect nylon filter | |||||||||
Outline Dimension | W | mm | 690 | 690 | 690 | 880 | 880 | 1200 | ||
D | mm | 440 | 440 | 440 | 470 | 470 | 440 | |||
H | mm | 1870 | 1870 | 1870 | 1870 | 1870 | 1870 | |||
Weight | kg | 75 | 85 | 87 | 97 | 110 | 145 |
The unit can achieve annual cooling operation in an ultra-wide environment range (-15 degrees to 55 degrees), which better meets the use of various electrical room control rooms; the unit's unique anti-corrosion process completely solves the air problems in paper mills and chemical plants The corrosive phenomenon of medium corrosive gas on the product to avoid the leakage of the product caused by the gas corroding the copper pipe.
Diverse forms and functions