Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner

Product Details
Customization: Available
After-sales Service: Within The Warranty to Provide Free Accessories
Warranty: 15 Months After Leaving The Factory
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
291
Year of Establishment
2003-05-22
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
  • Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
HASC2-200H
Air Tube Material
Galvanized Sheet
Corrosion Durability
Non-Standard Custom
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Mechanical Industry
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Air Volume
4700-6600m3/H
The Largest System of Heat
80kw
The Maximum Refrigerating Capacity
30kw
Machine Custom
According to The Demand for Custom-Made
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Trademark
HI-SURP
Origin
Yuyao China
HS Code
8415
Production Capacity
1000pieces/Year

Product Description

Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
Ceilling invisibility Commerial Air Cooler Fan coil for Air Terminal Cooling Solution   is widly used in 

*apartments
*buildings
*hotels
*hospitals etc

The unit has the functions of cooling and heating, and can achieve direct air supply over a long distance without ducts. It has the characteristics of saving space, greatly reducing one-time investment, and low operating costs. The unit adopts a spherical nozzle with superior performance as the air outlet, and the air supply angle can be adjusted manually within 60 degrees or using the controller, so that cold and hot air can reach the required position, creating a comfortable air-conditioning environment. The outlet direction of the spherical tuyere can be horizontal air supply or vertical downward air supply.
Detailed Photos

Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner

Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner
Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner

 

Product Parameters
Indoor unit model HASC2-200H HASC2-300H
Nominal cooling
capacity
(kW) 20 30
Nominal heating
capacity
(kW) 21 31.5
Energy regulation range 100-0
Nominal cooling
operating power
(kW) 7.2 10.6
Nominal heating
operating power
(kW) 6.9 10.1
Indoor unit operating power (kW) 1.1 2.2
Maximum power of
auxiliary electric
heating(optional)
(kW) 17.7 24.7
Supply power 380V 3N~50Hz
Air filter GN primary filter
Air supply air supply flow
rate(m3/h)
4200 6400
static pressure 1(Pa) 100 100
static pressure 2(Pa) 150 /
static pressure 3(Pa) 200 300
Fan type External rotor centrifugal fan
quantity 2 1
Auxiliary electric
heating (optional)
heater type PTC ceramic
power(kW) 9 12
Evaporator
parameters
copper tube type Inside threaded pipe Sleek tube
fin type Hydrophilic membrane window openings
Throttling method Thermal expansion valve
Connection method Thread Welding
  liquid tube
diameter(in)
φ1/2 φ5/8

Piping size
air tube diameter(in) φ3/4 φ1- 1/8
condensate
drainage pipe
DN20
Indoor unit
diamension
length(mm) 1480 1780
width(mm) 820 980
high(mm) 550 550
weight(kg) 130 260
noise(dB)A 66 68
Note:
1.Rated cooling capacity test conditions: outdoor dry bulb/wet bulb 35°C/24°C, indoor
dry bulb/wet bulb 27°C/ 19°C
2.Rated heat production test conditions: outdoor dry bulb/wet bulb 7°C/6°C, indoor
dry bulb 20°C
3.For heating at ambient temperatures below 0°C, electric heating is recommended.

4.The static pressure of the unit in the fan characteristics is selected as an integer
multiple of 50 between 1 and 3 for the given static pressure.
Packaging & Shipping

Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner

Company Profile

 

Hisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air ConditionerHisurp Factory Price Ceiling Mount Air-Cooled Ducted Air Conditioner

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier