Offshore Platform Marine Rooftop Packaged Unit

Product Details
Customization: Available
After-sales Service: Within The Warranty to Provide Free Accessories
Warranty: 15 Months After Leaving The Factory
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
291
Year of Establishment
2003-05-22
  • Offshore Platform Marine Rooftop Packaged Unit
  • Offshore Platform Marine Rooftop Packaged Unit
  • Offshore Platform Marine Rooftop Packaged Unit
  • Offshore Platform Marine Rooftop Packaged Unit
  • Offshore Platform Marine Rooftop Packaged Unit
  • Offshore Platform Marine Rooftop Packaged Unit
Find Similar Products
  • Overview
  • Application:
  • Photos
  • Product Parameter(example)
  • Our Advantages
  • Features:
  • Packing
Overview

Basic Info.

Model NO.
HS-WG17Q
Type
Marine Cooling Equipment Specific Air Conditioner
Air Tube Material
Galvanized Sheet
Corrosion Durability
Non-Standard Custom
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
The Ship
Mounting
Floor Standing
Lifetime
>20 years
Certification
CCC
Condition
New
Compressor Brand
Copeland/Dai.Kin/Panasonic/Hitachi
Refrigerant
R22, R404A, R407c, R134r
Refrigerating Capacity
7kw-86kw
Compressor Types
Piston Compressor
Fan
Low Noise Centrifugal Fan
The Condenser
High Efficiency Tube and Shell Heat Exchanger
Machine Custom
According to The Demand for Custom-Made
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Trademark
HI-SURP
Origin
China
HS Code
8415
Production Capacity
1000pieces/Year

Product Description

Application:

Marine air conditioner is widly used in 

*Marine
*offshore
*ship
*container  ship
*vessel

 

Photos

Offshore Platform Marine Rooftop Packaged Unit

Offshore Platform Marine Rooftop Packaged Unit
Offshore Platform Marine Rooftop Packaged Unit
Offshore Platform Marine Rooftop Packaged Unit

 

Product Parameter(example)
Water-cooled Marine Air Conditioner -- top air supply (R407C)
Parameter                                                            Model HS-WG10Q HS-WG17Q HS-WG27Q HS-WG35Q HS-WG42Q HS-WG50Q
Refrigeranting capacity KW 8.5/11.0 14.0/17.0 20.0/24.0 24.0/30.0 18.0*2/21.0*2 20.0*2/24.0*2
Electric heating KW 8 14 22 28 34 40
Power supply 3P-440-50HZ/60HZ
Refrigerant type   R407C
Compressor type piston Compressor
qty set 1 1 1 1 2 2
power kW 2.9/3.6 4.3/5.2 6.3/7.6 7.2/8.8 5.8*2/6.8*2 6.3*2/7.6*2
Condenser type    
water volume m3/h 3.2/3.9 5.1/6.1 7.2/8.6 8.8/10.7 12.8/15.2 14.4/17.2
connection pipe size DN 25 32 50 50 65 65
water resistance Kpa 50
Evaporator type   Copper tube string sleeve type
fin form   Corrugated copper fins/Corrugated hydrophilic film aluminum fins
Throttling method     External balanced thermostatic expansion value
Fan type Low noise centrifugal Fan
driving mode belt driven
power KW 0.55/0.86 0.55/0.86 1.1/1.27 1.1/1.27 2.2/2.53 2.2/2.53
air volume m3/h 1000/1200 15000/1800 2100/2500 2600/3000 23800/4400 4200/4900
external static pressure Pa 400
Safety protection device high / low pressure protection, current overload protection, water flow protection, Electronic time delay protection etc
Unit drain pipe DN   25
Outline dimension W(mm) mm 800 1050 1200 1450 1700 1900
D(mm) mm 550 580 700 700 800 900
H(mm) mm 1610 1610 1700 1700 1800 1800
Unit weight kg 265 300 460 540 600 680
Our Advantages

 

Offshore Platform Marine Rooftop Packaged Unit
Features:

Compressor
The compressor is the core of the refrigeration system. Compared with land-based air conditioners, the compressors of marine air conditioners operate in inclined swings, and the fuel supply problem is more prominent. Poor oil supply will cause serious damage to the compressor. The deep oil tank design ensures the oil supply of the compressor on the ship in a tilting and swaying environment. The anticorrosion of the compressor is sprayed with naval special anticorrosive paint after the outer surface is sandblasted.
Condenser
The condensers for marine air conditioners are divided into seawater water-cooled and air-cooled condensers. The seawater condenser is directly cooled by seawater. It is necessary to prevent the highly corrosive seawater corrosion and the smoothness of the refrigerant supply liquid when the hull is swaying. The air-cooled condenser needs to be protected from salt spray corrosion. The water-cooled condenser uses Bfe10-1-1 heat transfer tube with strong anti-corrosion ability, the end cover is made of cast aluminum bronze, and the tube sheet is made of (HA177-
2 / 16MnR) composite materials, and additional safety valves are added to ensure safety, and anti-potential corrosion equipment is added to the seawater side. For the liquid supply problem of the water-cooled condenser, add a liquid storage bag to the lower part of the condenser. The air-cooled condenser uses a copper sheet-covered copper tube heat exchanger to improve the resistance to salt spray.
·Evaporator
Marine evaporators are also divided into water-cooled and air-cooled. Corrosion protection still needs to be considered. The water-cooled evaporator uses a dry shell-and-tube evaporator, which is the same as the land-based evaporator, but still needs to consider the anti-corrosion measures on the outer surface of the evaporator, and add a plated steel shell on the outer surface to enhance the corrosion resistance of the evaporator. The air-cooled finned evaporator uses a high-efficiency copper tube jacketed type.
Throttling mechanism
In addition to throttling, the expansion mechanism also plays a role in regulating the flow of refrigerant into the evaporator. At present, externally balanced thermal expansion valves are commonly used in marine air conditioners.
System accessories
The main components of the refrigeration system are dry filters, oil storage tanks, gas-liquid separators, solenoid valves, sight glasses, pressure gauges, shock absorbers, high and low pressure protectors, etc., which are used to better detect the operation of the system and protect the operation of the system. Safety and reliability. Among them, the installation of marine air-conditioning accessories, such as sight glass, should be threaded to avoid welding. The marine air conditioner solenoid valve needs to be equipped with a manual control lever.
Selection of fan and motor
Marine fans and motors still need to consider anti-corrosion and anti-tilt factors. The impeller of the marine air conditioner fan requires strict dynamic balance correction and overspeed test. The material of the impeller is made of anti-corrosion aluminum alloy. The whole casing is welded to meet the requirements of ship strength, impact resistance and corrosion resistance. The selection of marine motors except when the ship periodically tilts up to 45 °. It is required that the motor can work reliably and can still work without damage when the long-term horizontal and vertical tilt reaches 15 °, and a filter must be installed to prevent electromagnetic interference.
Marine duct design
The main features of the circulating air piping system are small space, high heat generation, and very limited layout space on board. When designing the air duct, it is necessary to fully consider the vibration isolation, vibration reduction and noise reduction of the air duct, minimize the resistance loss, adjust the air volume and the actual space layout of the ship. A return air box should be provided at the air inlet and outlet respectively. In order to reduce the vibration transmission during the operation of the special air conditioner, a small piece of soft connection is connected between the rigid air pipe and the air inlet and outlet interface of the air conditioning equipment.

Design of cooling seawater pipeline
The ship's cooling water uses highly corrosive seawater, and the sea cement sand content is relatively high. Generally, the cooling seawater flow is designed according to the temperature difference of 4 ºC. The water flow rate in the tube is designed according to 1 ~ 1.5m / s, and the fluctuation range of the cooling seawater temperature is -2 ~ 32 ºC.An electric three-way regulating valve is installed between the inlet and outlet of the cooling seawater. In order to reduce vibration transmission and facilitate docking, a hose connection should be used between the pipeline and the air conditioning interface

Design of cooling seawater pipeline
The frame and leaking parts must be painted and anticorrosive, and the electrical components must be anticorrosive materials and electromagnetic interference.
 

Packing

 

Offshore Platform Marine Rooftop Packaged Unit
Offshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged UnitOffshore Platform Marine Rooftop Packaged Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier