Application:
The Hisurp Soft Starting Free Cooling Data Center Server Room Inverter Precision Air Conditioner CCU is widely used in
*data/computer rooms
*switch rooms
*hospitals
*museums
*laboratories
*control rooms
*precision machining workshops demanding thermostat
Parameter Chart:
HTHA-8S HTHAZ-8S |
HTHA-10S HTHAZ-10S |
HTHA-12S HTHAZ-12S |
HTHA-17S HTHAZ-17S |
HTHA-20S HTHAZ-20S |
HTHA-22S HTHAZ-22S |
HTHA-25S HTHAZ-25S |
HTHA-30S HTHAZ-30S |
|||
Unit | Cooling Capacity | (kW) | 7.9 | 10.3 | 12.6 | 16.7 | 19.2 | 22.5 | 25.8 | 30.6 |
Heating Capacity (Electric Heating) | (kW) | 4.5 | 6 | 6 | 9 | 12 | 12 | 15 | 18 | |
Air Volume | (m3/h) | 1500 | 2400 | 2700 | 3800 | 4300 | 4900 | 5600 | 6600 | |
External Static Pressure | (Pa) | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
Filtering | GN-Level Initial Effect | |||||||||
Temperature Control | Range and Accuracy | 18ºC~28ºC±1ºC | ||||||||
Humidity Control | Range and Accuracy | 50~70%RH±10%RH | ||||||||
Energy Regulating | Range | 100-66-0 | ||||||||
Power Supply | 3P-AC380V/50HZ | |||||||||
Refrigerating Power | (kW) | 2.9 | 3.8 | 4.7 | 6.2 | 7.2 | 8.4 | 9.6 | 11.4 | |
Max Operating Power | (kW) | 8.3 | 11.0 | 12.1 | 17.1 | 21.3 | 22.9 | 27.5 | 32.8 | |
Indoor Unit | Evaporator | Type | Copper Tube-Aluminum Fin Type | |||||||
Fin | Hydrophilic Shutter-Type Aluminum Fins | |||||||||
Windward Area (m2) | 0.17 | 0.28 | 0.31 | 0.44 | 0.50 | 0.57 | 0.65 | 0.76 | ||
Refrigerant | Throttling | Thermal Expansion Valve | ||||||||
Fan | Type | Low Noise Centrifugal Fan | ||||||||
Driving | Direct Drive | Direct Drive | Direct Drive | Direct Drive | Direct Drive | Direct Drive | Direct Drive | Direct Drive | ||
Electrode Humidifier | Power (kW) | 2.25 | 3.75 | 3.75 | 3.75 | 3.75 | 3.75 | 3.75 | 3.75 | |
Humidifying Capacity (kg/h) | 3 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | ||
Inlet Diameter | DN15 | DN15 | DN15 | DN15 | DN15 | DN15 | DN15 | DN15 | ||
Electric Heater | Type | PTC Ceramic | PTC Ceramic | PTC Ceramic | PTC Ceramic | PTC Ceramic | PTC Ceramic | PTC Ceramic | PTC Ceramic | |
Power(kW) | 4.5 | 6 | 6 | 9 | 12 | 12 | 15 | 18 | ||
Tube Dimensions (Diameter) |
Liquid Pipe (in) | φ3/8×1 | φ1/2×1 | φ1/2×1 | φ1/2×1 | φ1/2×1 | φ5/8×1 | φ5/8×1 | φ5/8×1 | |
Gas Pipe(in) | φ5/8×1 | φ3/4×1 | φ3/4×1 | φ3/4×1 | φ3/4×1 | φ7/8×1 | φ1-1/8×1 | φ1-1/8×1 | ||
Drain Pipe | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | DN20 | ||
Outline Dimension | L(mm) | 900 | 900 | 900 | 1200 | 1400 | 1400 | 1400 | 1400 | |
W(mm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 600 | ||
H(mm) | 1960 | 1960 | 1960 | 2050 | 2050 | 2050 | 2050 | 2250 | ||
Weight(Kg) | 136 | 146 | 165 | 225 | 275 | 280 | 285 | 335 | ||
Noise(dB)A | 53 | 56 | 59 | 61 | 62 | 63 | 64 | 65 | ||
Outdoor Unit | R22 Outdoor Unit Model | HAS-80WSL-E | HAS-100WSL-E | HAS-120WSL-E | HAS-170WSL-E | HAS-200WSL-E | HAS-220WSL-E | HAS-250WSL-E | HAS-300WSL-E | |
R410a Outdoor Unit Model | HASZ-80WSL-E | HASZ-100WSL-E | HASZ-120WSL-E | HASZ-170WSL-E | HASZ-200WSL-E | HASZ-220WSL-E | HASZ-250WSL-E | HASZ-300WSL-E | ||
Qty. | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Power Supply | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | 3P-AC380V/50HZ | ||
Refrigerant | Type | R22/R410a | R22/R410a | R22/R410a | R22/R410a | R22/R410a | R22/R410a | R22/R410a | R22/R410a | |
Filling Amount(kg) | 2.9 | 3.7 | 4.5 | 6.0 | 6.9 | 8.1 | 8.3 | 10.2 | ||
Compressor | Type | Rator Type | ScrollType | ScrollType | ScrollType | ScrollType | ScrollType | ScrollType | ScrollType | |
Qty. | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Condenser Type | Copper Tube-Aluminum Fin Type | |||||||||
Fan Part | Fan Type | Axial Flow Air Blade | ||||||||
Fan Model | ABS490 | ABS450 | ABS450 | RZLC600 | RZLC600 | RZLC650 | RZLC650 | RZLC750 | ||
Qty. | 1 | 2 | 2 | 1 | 1 | 1 | 1 | 1 | ||
Air Volume (m3/h) | 3800 | 5600 | 5600 | 8040 | 8040 | 9930 | 9930 | 14360 | ||
Power(kW) | 0.15 | 0.1 | 0.1 | 0.37 | 0.37 | 0.55 | 0.55 | 1.1 | ||
Outline Dimension | L(mm) | 953 | 953 | 953 | 760 | 760 | 850 | 850 | 915 | |
W(mm) | 353 | 353 | 353 | 760 | 760 | 850 | 850 | 915 | ||
H(mm) | 840 | 1235 | 1235 | 1270 | 1270 | 1300 | 1300 | 1300 | ||
Weight(Kg) | 82 | 136 | 136 | 151 | 180 | 220 | 220 | 252 | ||
Noise(dB)A | 63 | 66 | 66 | 67 | 68 | 72 | 72 | 76 | ||
Remarks: 1,Rated cooling capacity test conditions: outdoor DB/WB 35°C/24°C, indoor DBl/WB 23°C/17°C |
The outdoor unit design is light and compact,let the installation cost is greatly reduced
Detailed Introduction:
1.Equipped with a complete failure alarm indicator system.
2.Six horsepower adopt independent dual system and three-level electric heating system.
3.Using imported high-quality electrode humidifiers, which can use various tap water, and tap water can be used directly without water treatment; the humidifier can adjust the steam output, so that the unit humidity can be adjusted very finely to achieve high control accuracy.
4.Simple design makes maintenance and maintenance extremely convenient. All the accessories of the unit can be inspected and repaired directly from the front, and there is no need to stop the machine.
5.Widely used in workshops,centralized control rooms in machinery manufacturing, steel, chemical, electronics, pharmaceutical and other industries, as well as restaurants, hotels, clubs, and other commercial air conditioning places to meet industrial process air conditioning and commercial comfort in different environments.
Packing:
Hot selling items (click the pics to view more):
Crane cab / High temp resistant industrial AC Unitary air cooled / Packaged water cooled AC Precision / Data center / Laboratory ACMarine air conditioner Enclosure / Panel cooler / Electrical room air conditioner Modular air cooled heat pump scroll chiller