Hisurp PAC Air Conditioning Unit for Data Center

Product Details
Customization: Available
After-sales Service: Within The Warranty to Provide Free Accessories
Warranty: 15 Months After Leaving The Factory
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
291
Year of Establishment
2003-05-22
  • Hisurp PAC Air Conditioning Unit for Data Center
  • Hisurp PAC Air Conditioning Unit for Data Center
  • Hisurp PAC Air Conditioning Unit for Data Center
  • Hisurp PAC Air Conditioning Unit for Data Center
  • Hisurp PAC Air Conditioning Unit for Data Center
  • Hisurp PAC Air Conditioning Unit for Data Center
Find Similar Products
  • Overview
  • Application:
  • Detailed Photos
  • Product Parameter(example)
  • Product Description
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
HTHA-8C
Air Tube Material
Galvanized Sheet
Corrosion Durability
Non-Standard Custom
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Precision Machine Room
Mounting
Floor Standing
Lifetime
>20 years
Certification
RoHS, UR, ISO, CE, CCC
Condition
New
Compressor Brand
Copeland/Dai.Kin/Panasonic/Hitachi
Refrigerating Capacity
7.9kw-280kw
The Heating
4.5kw-144kw
Refrigerant
R22, R407c, R410A, R134A
Compressor Types
The Vortex Type
Fan
Low Noise Centrifugal Fan
Machine Custom
According to The Demand for Custom-Made
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Trademark
HI-SURP
Origin
China
HS Code
8415
Production Capacity
1000pieces/Year

Product Description

Application:
 

Precision Air Conditioner with Scroll Compressor  is widely used in

*machinery manufacturing
*steel, chemical, electronic, pharmaceutical and other industries workshop
*centralized control room
*restaurants
*hotels
*clubs
*data center
*other commercial air conditioning places

Detailed Photos
Hisurp PAC Air Conditioning Unit for Data Center
Hisurp PAC Air Conditioning Unit for Data Center

Product Parameter(example)

 

Ceiling Type

                                Model     HTHA-8C          HTHA-10C             HTHA-12C           HTHA-17C         HTHA-20C        
          Project               Parameters
Units Features Refrigerating Capacity (kW) 7.9 10.3 12.6 16.7 19.2
Heating Capacity(Electric Heating) (kW) 4.5 6 6 9 12
Circulation Air Flow (m3/h) 1500 2400 2700 3800 4300
External Static Pressure (Pa) 60~100 60~150 60~150 60~200 60~200
Filtering Efficiency   GN-Level Initial Effect GN-Level Initial Effect GN-Level Initial Effect GN-Level Initial Effect GN-Level Initial Effect
Temperature Control Range and Precision   18ºC~28ºC±1ºC 18ºC~28ºC±1ºC 18ºC~28ºC±1ºC 18ºC~28ºC±1ºC 18ºC~28ºC±1ºC
Humidity Control Range and Precision   50~70%RH±10%RH 50~70%RH±10%RH 50~70%RH±10%RH 50~70%RH±10%RH 50~70%RH±10%RH
Range of Energy Regulating   100-66-0 100-66-0 100-66-0 100-66-0 100-66-0
Power Supply   3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ
Refrigerating Power (kW) 2.9  3.8  4.7  6.2  7.2 
Max Operating Power (kW) 8.3  11.0  12.1  17.1  21.3 
Indoor Unit Evaporator Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type
Fin Form Hydrophilic Shutter-Type Aluminum Fins Hydrophilic Shutter-Type Aluminum Fins Hydrophilic Shutter-Type Aluminum Fins Hydrophilic Shutter-Type Aluminum Fins Hydrophilic Shutter-Type Aluminum Fins
Windward Area(m2) 0.17  0.28  0.31  0.44  0.50 
Refrigerant Throttling Mode Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve
Fan Type Low Noise Centrifugal Fan Low Noise Centrifugal Fan Low Noise Centrifugal Fan Low Noise Centrifugal Fan Low Noise Centrifugal Fan
Driving Method Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive
Electrode Humidifier Power(kW) 2.25 3.75 3.75 3.75 3.75
Humidifying Capacity(kg/h) 3 5 5 5 5
Inlet Diameter DN15 DN15 DN15 DN15 DN15
Electric Heater Type of Electric Heater PTC Ceramic PTC Ceramic PTC Ceramic PTC Ceramic PTC Ceramic
Power kW 4.5 6 6 9 12
Tube Dimensions Diameter of Liquid Pipe(in) φ3/8×1 φ1/2×1 φ1/2×1 φ1/2×1 φ1/2×1
Diameter of Gas Pipe(in) φ5/8×1 φ3/4×1 φ3/4×1 φ3/4×1 φ3/4×1
Diameter of Drain Pipe DN20 DN20 DN20 DN20 DN20
Outline Dimension L(mm) 1280 1480 1480 1780 1780
W(mm) 820 820 820 980 980
H(mm) 550 550 550 550 550
Weight(Kg) 126 138 142 166 178
Noise(dB)A 59 62 62 63 63
Outdoor Unit R22 Outdoor Unit Model HAS-80WSL-E HAS-100WSL-E HAS-120WSL-E HAS-170WSL-E HAS-200WSL-E
R410a Outdoor Unit Model HASZ-80WSL-E HASZ-100WSL-E HASZ-120WSL-E HASZ-170WSL-E HASZ-200WSL-E
Numbers 1 1 1 1 1
Power Supply 3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ 3P-AC380V/50HZ
Refrigerant Refrigerant Type R22/R410a R22/R410a R22/R410a R22/R410a R22/R410a
Filling Amount(kg) 2.9  3.7  4.5  6.0  6.9 
Compressor Type Rator Type Vortex Type Vortex Type Vortex Type Vortex Type
Numbers 1 1 1 1 1
Condenser Type   Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type Copper Tube-Aluminum Fin Type
Fan Part Fan Type Axial Flow Air Blade Axial Flow Air Blade Axial Flow Air Blade Axial Flow Air Blade Axial Flow Air Blade
Fan Model ABS490 ABS450 ABS450 RZLC600 RZLC600
Numbers 1 2 2 1 1
Air Volume(m3/h) 3800 5600 5600 8040 8040
Power(kW) 0.15 0.1 0.1 0.37 0.37
Outline Dimension L(mm) 953 953 953 760 760
W(mm) 353 353 353 760 760
H(mm) 840 1235 1235 1270 1270
Weight(Kg) 82 136 136 151 180
Noise(dB)A 63 66 66 67 68

Remarks:
1. Rated cooling capacity test conditions: outdoor dry ball/wet ball 35°C/24°C, indoor dry ball/wet ball 23°C/17°C
2. The static pressure of the unit in the fan features is selected according to the integer multiple of 50 within the given static pressure range.

 

Product Description

The constant temperature and humidity unit is equipped with a Chinese display operator. The working status and parameter query settings are all displayed in Chinese. It is also equipped with a complete fault alarm indicator system, which greatly facilitates the user. Microcomputer has more constant dehumidification control energy levels than other manufacturers. Make the control more precise and avoid large deviation of indoor temperature fluctuation during adjustment.

The constant temperature and humidity unit is equipped with a Chinese display operator. The working status and parameter query settings are all displayed in Chinese. It is also equipped with a complete fault alarm indicator system, which greatly facilitates the user. More, make the control more accurate, avoid large temperature and humidity fluctuations during adjustment
Six or more models adopt independent dual system and three-level electric heating system, which makes the temperature and humidity adjustment of the unit more precise, more efficient and energy saving, and achieves control accuracy.
All models use imported high-quality electrode humidifiers, which can use a variety of tap water, and tap water can be used directly without water treatment; the humidifier can adjust the steam output, making the unit humidity adjustment very fine to achieve high control accuracy.
The design of the unit is flexible. Wellcome has a variety of methods such as direct air, upper air supply and lower air supply, which can easily meet the needs of field installation. Adopting the skeleton structure, the rigidity of the internal fittings is higher, which reduces the vibration and noise of the unit. Each shell plate is pasted with a sufficient thickness of thermal insulation and sound-absorbing materials, and can be easily removed.
The fan adopts forward curved multi-wing centrifugal double-suction impeller, and the impeller has no noise vibration during long-term operation to ensure a high degree of air supply effect. The belt drive can flexibly change the parameters such as unit air volume and external pressure, so Matching with the actual project; the fan comes with a motor adjustment plate, which can easily adjust the tightness of the belt.
Smart and simple design makes maintenance and repair extremely convenient. All the unit's accessories can be inspected and repaired directly from the front, and there is no need to stop.
Refrigeration range
The cooling capacity is from 7kW to 300kW.. It is widely used in workshops and centralized control rooms in machinery manufacturing, steel, chemical, electronics, pharmaceutical and other industries, as well as restaurants, hotels, clubs, and other commercial air-conditioning places to meet industries in different environments. The need for process air conditioning and commercial comfort air conditioning.
No matter whether it is reconstruction or reconstruction, since there is no need to set up a dedicated air-conditioning room, the freedom to choose a place to install is large, so that your space of responsibility is wide. At the same time, FFU can be used in a wide range of hospital waiting rooms, nursing staff offices, lounges, etc. The problem of clean air.

Packaging & Shipping


Hisurp PAC Air Conditioning Unit for Data Center
Hisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data CenterHisurp PAC Air Conditioning Unit for Data Center






 