Dimensions:
Product Parameter(example)
Model | HAHU(Z)-35H | HAHU(Z)-40H | HAHU(Z)-45H | HAHU(Z)-50H | ||
Parameter | ||||||
Unit charactries | Cooling Capacity | (kW) | 35 | 40 | 45 | 50 |
Heating Capacity (Heat Pump) | (kW) | 36.8 | 42.0 | 47.3 | 52.5 | |
)Auxiliary electric heating (optional) | (kW) | 12.0 | 18.0 | 18.0 | 24.0 | |
Circulation Air Flow | (m3/h) | 6600 | 7600 | 8200 | 9400 | |
ESP Range | (Pa) | 100~400 | 100~400 | 200~500 | 200~500 | |
Temperature Control Range &Accuracy | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | 18ºC~30ºC±1ºC | ||
Engery Regulation | % | 0-100 | 0-100 | 0-50-100 | 0-50-100 | |
Power Supply | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | 3P-AC380V/50HZ/N/PE | ||
Operation Power(Minnimum static pressure) | (kW) | 13.7 | 15.6 | 17.6 | 19.5 | |
Electrical Parameters-No elctric heating | Max.Operation Power | 17.8 | 20.3 | 22.9 | 25.4 | |
Ref.Current | 33.7 | 38.5 | 43.3 | 48.1 | ||
wire inlet specification (mm2) | 10.0 | 10.0 | 10.0 | 10.0 | ||
Electric Parameters-Ekectric heating | Max.operation Power | 29.8 | 38.3 | 40.9 | 49.4 | |
Ref.Current | 56.4 | 72.6 | 77.4 | 93.5 | ||
wire inlet specification (mm2) | 16.0 | 16.0 | 25.0 | 25.0 | ||
Air Regulant Section | primary filter | Type$Class | panelG3/G4 | panelG3/G4 | panelG3/G4 | panelG3/G4 |
Middle filter(optional) | Type$Class | PanelFB5 | PanelFB5 | PanelFB5 | PanelFB5 | |
Evaporator | Type | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | Hydrophilic shutter type aluminium fins | |
Windward Speed | <=2.5 | <=2.5 | <=2.5 | <=2.5 | ||
Throttling Mode | expansion value | expansion value | expansion value | expansion value | ||
Auxiliary Electric heating(optional) | Electric heating mode | PTC cermics | PTC cermics | PTC cermics | PTC cermics | |
Power(kW) | 12 | 18 | 18 | 24 | ||
Pipe Diameter | DN | DN25 | DN25 | DN25 | DN25 | |
Supply Fan | Type | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | low noise centrifugal fan | |
transmission mode | belt drive | belt drive | belt drive | belt drive | ||
Fan Type | KTS12-12 | KTS15-15 | KTS15-15 | KTS15-15 | ||
Fan Quantity | 1 | 1 | 1 | 1 | ||
Fan Dimension | 395×341 | 471×404 | 471×404 | 471×404 | ||
compressor condesder Section\ | Compressor | Type | Vortex | Vortex | Vortex | Vortex |
Quantity | 1 | 1 | 2 | 2 | ||
Refrigerat | Refrigerant Model | R410A/R22 | R410A/R22 | R410A/R22 | R410A/R22 | |
filling Capacitykg | 10.5 | 12.0 | 13.5 | 7.5×2 | ||
Condenser | Type | vCopper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | Copper tube Aluminiun fins | |
Fan Section | Fan type | Axial fan | Axial fan | Axial fan | Axial fan | |
fan Model | RZLC750 | RZLC750 | RZLC650 | RZLC650 | ||
Quantity | 1 | 1 | 2 | 2 | ||
Air Flow(m3/h) | 14360 | 14360 | 9930 | 9930 | ||
Power(kW) | 1.1 | 1.1 | 0.55 | 0.55 | ||
Outline Dimension | Length(mm) | 1760 | 1760 | 1860 | 1860 | |
Width(mm) | 1300 | 1300 | 2000 | 2000 | ||
Height(mm) | 1660 | 1660 | 1760 | 1760 | ||
Weight(Kg) | 560 | 600 | 660 | 700 | ||
Noise(dB)A | 76 | 68 | 72 | 72 | ||
Note: | ||||||
1, Rated Refrigeration Capacity TestCondition:Outdoor dry ball 35ºC,indoor dry ball/wet ball 27ºC/19ºC | ||||||
2,Rated heating test conditon:Outdoor dry ball/wet ball 7ºC/6ºC,indoor dry ball/wet ball 20ºC | ||||||
3,The ambient temperature is below 0ºC when heating ,it is recommed to use electric heating | ||||||
4,The static pressure of the unit in the fan characteristics is selected as an integer multiple of 50 within the given static pressure range. |
Details:
1. Heating and cooling heat pump type, single cooling plus electric heating type, or single cooling plus steam (hot water) heating type.
2. Easy installation and maintenance
3. Fully enclosed compressor. Compressor and the air supply fan have vibration damping devices. Operation is quiet, so the installation basis of the unit is simple.
4. Provides a double-layer washable primary filter. Disassembly and cleaning are simple and convenient.
5. Not occupy the indoor area, and the noise during the operation of the indoor inorganic group.
5. Unit has high and low pressure protection, overcurrent protection, phase sequence protection and other functions with high reliability. Durable.
6. Aluminum profile frame structure and sheet metal frame structure can select.
7. Microcomputer, large LED screen, has the function of timing switch, real-time clock display, etc. Optimized unit monitoring logic, well-designed unit operating data and fault alarm full code query and prompt functions, easy to operate.
8. Widely used in various large-space civil, commercial buildings and industrial plants; such as large conference centers, stadiums, exhibition centers, large supermarkets, theaters, electronic plants,desert etc.
Packing